2024 Hilti firestop systems - Life safety in buildings relies greatly on firestopping that performs as intended. Hilti is committed to continuously contributing to improved life safety of buildings by developing …

 
Seamless firestop management. Integrate your firestopping data for more transparency and decreased risk at every stage of the project. Our Documentation Manager application …. Hilti firestop systems

Hilti passive fire protection and firestop systems limit the spread of fire and smoke in fire-rated walls, floors and compartments to ensure life safety and ...Features. Hilti Endo-Shield is the industry’s first LBP (Low Bio Persistent) endothermic mat for passive fire protection. Low bio persistent materials allow fibers to easily clear from the lungs compared to ceramic fibers, resulting in a safer non-carcinogenic product for the installer. Faster, easier fire protection – high flexibility and ... A firestop system’s water resistance is therefore an important characteristic in addition to its main function. Hilti firestop systems are therefore not only tested and approved internationally in accordance with passive fire prevention requirements, but also in terms of their water resistance in accordance with the applicable standards.Hilti Firestop Systems. WL 3395. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. September 14, 2020. System No. W-L-3395 . Page: 4 of 4. Table 2 - CFM per FT2 of Opening at Ambient and 400F. Hilti Firestop Systems. Type and Number of Devices in CFS-SL GP (CAP - Item 3A; Devices - Any combination of Items 3BFeatures. Hilti Endo-Shield is the industry’s first LBP (Low Bio Persistent) endothermic mat for passive fire protection. Low bio persistent materials allow fibers to easily clear from the lungs compared to ceramic fibers, resulting in a safer non-carcinogenic product for the installer. Faster, easier fire protection – high flexibility and ... Oh how I love it when two of my favorite things are combined! This is exactly what has happened when Kinkless took Getting Things Done and built a system (KGTD) around OmniOutliner. Oh how I love it when two of my favorite things are combin...Hilti Firestop Systems SheetDrawing No. HILTI, Inc. Date Scale Saving Lives through Innovation and Education HWD 1 of 2 1/4" = 1" UL/cUL SYSTEM NO. HW-D-0824a ASSEMBLY RATING = 1-HR. OR 2-HR. CLASS II MOVEMENT CAPABILITIES - 25% COMPRESSION OR EXTENSION TOP OF WALL JOINT : GYPSUM SHAFT WALL ASSEMBLY CROSS-SECTIONAL VIEW Plano, Texas USA (800 ...5. hilti cfs-s sil gg firestop silicone sealant or hilti cfs-s sil sl firestop silicone sealant (floors only) (see table for depth). 6. minimum 1/2" bead hilti cfs-s sil gg firestop silicone sealant applied at point of contact. notes : 1. maximum diameter of opening = 32" (for normal concrete) or 7" (for precast (hollow-core) concrete). 2.Hilti Firestop Systems L-Rating N/A Reproduced by HILTI, Inc. Courtesy of Intertek Group June 20, 2014 Design No. CEJ 245 P (HI/BP 135-01) PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2 1/4-HR. 2 1/4-HR. T-RATING 2 1/4 …A: When first accessing the Hilti Construction Platform, you will see five (5) options allowing a range of services and functionality for Engineering Judgments to firestop system search and submittals: Hilti fire protection specialists have performed extensive testing in both through-penetration and construction joint firestop applications.Hilti Firestop Systems. Page: 2 of 2. System No. HW-D-0259. HWD 0259. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. June 23, 2023 D. Spray-Applied Fire Resistive Material* — Steel floor units and structural steel beam to be sprayed with the thickness of material specified inHilti Firestop boards - CP 670 Firestop board - Firestop coated board system with wide approval range for sealing medium to large openingsHilti (Gt. Britain) Limited, 1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY Telephone: 0800 886 100 . HILTI CP 606 . Flexible Firestop Sealant . The enclosed pages are taken from the . Hilti Firestop Systems Manual . Edition April 2011 . Supported by additional standard details . For Material Safety data sheetsTel (800) 879-8000 or Hilti (Canada) Corporation, Mississauga, Ontario (800) 363-4458 website: www.us.hilti.com or www.hilti.ca.com Substitutions: Not permitted. Single Source: Obtain firestop documentation manager software and firestop systems for each type of penetration and construction condition indicated only from a single manufacturer.Hilti Firestop Systems. Page: 2 of 2. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. October 28, 2019. System No. W-L-7277. WL 7277. 1. Wall Assembly — The 1 or 2 hr fire rated framed gypsum board wall assembly shall be constructed of the materials and in the mannerOur Fire Protection Consultant visit the sites of our customers and give seminars on the know-how about the Firestop system and the selected application as per the need of customer. These trainings include a wide spectrum of Firestop knowledge ranging from Products, Application, Approvals, Installation procedure, Documentation etc.5. as an alternate to utilizing cp 648e wrap strips with retaining collar, hilti cp 643n firestop collar may be used when coupling is not installed. every fastening hook of firestop collar to be attached to gypsum wall with 1-1/2" long steel drywall or laminate screws with 3/4" steel washers. wl 2 of 2-ul system no. w-l-2411 f-rating = 1-hr. or ...Hilti Firestop Systems Design Number HI/AF 120-01Hilti Corporation HI/AF 120-01 Applied Fireproofing Hilti CPF-ES Endo-Shield ASTM E1725 Ratings: Min. 1 in. Tubing, 3 Layers of Hilti Endo-Shield: 1 Hour Min. 1 in. Tubing, 5 Layers of Hilti Endo-Shield: 2-1/2 Hour Min. 4 in. Tubing, 4 Layers of Hilti Endo-Shield: 2 Hour Reproduced by HILTI, Inc.System No. W-J-8035 SECTION A-A WJ 8035 Page: 1 of 3 A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 21, 2015 F Rating - 2 Hr T Rating - 0 Hr A 5A 5B 5B 1 2 3 2 4 3 Hilti Firestop Systems 1. Wall Assembly — Min 5 in. (127 mm) thick reinforced lightweight or normal weight (100-150 pcf) concrete. Wall may also be ... One example is the ASTM E-3037 standard, published in November of 2016 and formally titled “Test Method for Measuring Relative Movement Capabilities of Through-Penetration Firestop Systems.” This new standard sets testing guidelines to assess the movement capability of through penetration products such as pipe and cable penetrations.FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FIRESTOP DEVICE FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY Description 5N76 Technical Data Pipe outside dia (in.) Collar Collar No. of outside Height hooks and dia. (in.) (in.) fasteners CP 643-50/1.5"N 1.4–2.0 2.80.9 2 CP 643-63/2"N 2.0–2.5 3.41.3 2Life safety in buildings relies greatly on firestopping that performs as intended. Hilti is committed to continuously contributing to improved life safety of buildings by developing …One example is the ASTM E-3037 standard, published in November of 2016 and formally titled “Test Method for Measuring Relative Movement Capabilities of Through-Penetration Firestop Systems.” This new standard sets testing guidelines to assess the movement capability of through penetration products such as pipe and cable penetrations.Our in-house lab conducts firestop testing in accordance with ASTM E814 / UL 1479 for through-penetration firestop systems and ASTM E1966 / UL 2079 for construction-joint firestop systems. That means you can trust the F-rating and T-rating for each Hilti firestop system assembly.Firestop sealants, sprays and coatings. Accessories for firestop & fire protection. Software for firestop and fire protection. Over 30 years of experience in providing internationally …Identification sticker QR (2000) set New product. Item # 2096830. Identification signage for firestop installations, making them uniquely identifiable for monitoring and inspection purposes using Hilti Documentation Manager softwareHilti faz com que as obras operem de forma mais simples, rápida e segura. Temos mais de 30 anos de experiência no fornecimento de sistemas contra incêndios aprovados e …DAP PRODUCTS INC — DAP Firestop Sealant EGS NELSON FIRESTOP — ES 1399 Sealant HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP601S, CFS-S SIL GG, CP606, FS611A, FS-ONE Sealant or FS-ONE MAX Intumescent Sealant 3M COMPANY — FB 1000NS, FB 2000, FB 2000+, FD-10+, CP 25 WB+ NATIONAL GYPSUM CO — FS-90. Hilti Firestop Systems. System No ...(Firestop Clash Management) plugin uses clash detection to find locations where penetrants meet fire-rated barriers and automatically selects the appropriate firestop systems. It removes the complexity of designing firestop systems and ensures that when it comes time for construction, the systems selected provide the fastestOur Hilti Firestop Documentation Manager helps you to document your installations on the jobsite and create detailed reports. We also test our firestop products to exacting international standards and all our systems and software are based on more than 30 years of Hilti research and development.Simple Installations — Hilti firestop products arrive ready to use on your jobsite. Installation instructions and quick reference videos make the installing process quick and easy. System Approvals — Hilti provides firestop systems that can be used both locally and nationally in compliance with corresponding codes and regional regulations.Hilti passive fire protection and firestop systems limit the spread of fire and smoke in fire-rated walls, floors and compartments to ensure life safety and ...FIRESTOP DEVICE FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 5N76 CP 680-M in concrete over wood forms CP 680-P and CP 680-PX over metal deck CP 680-M over metal deck Hilti (Canada) Corp. 1-800-363-4458 www.hilti.caHilti Firestop Systems Page: 1 of 3 Reproduced by HILTI, Inc. Courtesy of Intertek Group December 26, 2019 2D 2C 2B 2C FOIL FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING2 Hour2 Hour T-RATING 0-1 Hour (see Item 2G) 0-1 Hour (see Item 2G) APPLICATION THICKNESS 1/8 in. wet film (1/16 in. dry)Hilti Academy. Select a course and let the learning begin. If you have not yet registered, you will first be directed to our registration page. Visit Hilti Academy. Hilti has power tools, grinders, drills, and saws as well as fasteners, anchors, design and layout software and services for construction professionals.<iframe src="https://www.googletagmanager.com/ns.html?id=GTM-WN2QZ7Q" height="0" width="0" style="display: none; visibility: hidden" title="Google Tag Manager ...Every Hilti product and system is backed with research, training, software, service and support. We also test our firestop products to exacting international standards and all our systems and software are based on more than 30 years of Hilti research and development. We are inspired to make a difference in our customers’ businesses. Hilti Firestop Systems Page: 1 of 3 Firestop Joint Spray CFS-SP WB Silicone Joint Spray CFS-SP SIL F-Rating120 Minutes T-Rating60 Minutes CyclingNA Design No. HI/BPF 120-17HI/BPF 120-17 PERIMETER FIRE BARRIER SYSTEM Firestop Joint Spray CFS-SP WB ASTM E 2307 Table 1. L-Rating <1.0 SCFM/LF Reproduced by HILTI, Inc. Courtesy of …Hilti Firestop Systems Manual Pages for Hilti CP 617 L FS 010 - 02 Hilti CP 617 Electrical Sockets, Switches - Drywall Robust Details Approval letter Data summary Additional Properties of CP 617 seals Data summary CP 617-Fire Rated Sealant – BREEAM Criteria summary Data summary CP 617-Fire Rated Sealant - NBS specification clauses 30 YEARSAttach Hilti Firestop Composite Sheet, foil facing down with Hilti X-GN 20 MX (3/4”) Nails with Hilti R 36-0.6 (1-1/4”) ECO fender washers spaced 4” maximum O.C. or Hilti KH-EZ 1/4”x1-7/8” Screw Anchors with 1-1/4” fender washers spaced at 6” (150 mm) maximum O.C. Install appropriate Hilti™ Fire Barrier product to firestopSeamless firestop management. Integrate your firestopping data for more transparency and decreased risk at every stage of the project. Our Documentation Manager application …May 21, 2020 - Hilti has developed firestop solutions for an increasingly popular nonmetallic pipe: High Density Polyethylene (HDPE). Hilti firestop system C-AJ-2770 has been updated to accommodate HDPE pipe (SDR 11) that can range in size from 1-1/2” to 6”. The solution involves the “tuck-in” method using Hilti CP 648E Wrap Strip.Plan, install and manage firestop solutions. Hilti's Firestop Selector can help trades, firestop specialty contractors and architects be more productive on the jobsite and in the …Hilti Firestop Systems. Page: 2 of 3. System No. HW-D-0049. HWD 0049. 1A. Roof Assembly — (Not Shown) — As an alternate to the floor assembly, a fire rated fluted steel deck roof assembly may be used. The roof assembly shall be constructed of the materials and in the manner described in the individual P900 Series Roof-Ceiling Design in the ... Seal cable penetrations with our modular firestop solutions, designed to create water-, smoke- and gas-tight barriers in energy and industry projects both onshore and offshore ... Cable transit systems. ... Customer Service 1-800-879-8000 Find Hilti Store Find Authorized Distributors and Rental Locations Request a call back Send a message.Hilti Firestop Systems System No. C-AJ-3386 CAJ 3386 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. November 15, 2021 3. Hilti Firestop Systems System No. F-A-1207 SECTION A-A FA 1207 1. Floor Assembly —Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete.Hilti Firestop Systems. Page: 2 of 2. 1. Wall Assembly — The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: Firestop coating system and mortar Page 155 Page 156 Firestop wrap and foam Firestop wrap stirp CP 648-E Firestop foam CP 620 Page 157 Page 158 Constrution chemicals filling foam Filling form CF-F Page 159 Accessories Accessories for firestop sealants and firestop foams Page 160Preformed firestop blocks for sealing penetrations with cables. LEED VOC: 5.4 g/l. Maximum wall opening (WxH): 1000 x 1000 mm. Storage and transportation temperature range: -5 - 40 °C. More technical data. Customers also searched for cables , electrical , passive or insulation.Hilti Firestop Saving lives through innovation and education Product information DBS • 03/22 HIGH-PERFORMANCE INTUMESCENT FIRESTOP SEALANT FS-ONE MAX Product description • Intumescent (expands when exposed to fire) firestop sealant that helps protect combustible and non-combustible penetrations for up to 4 hours fire rating Applications for usePassive fire protection systems are designed to stop the spread of flames, smoke and toxic gases in a fire. They block gaps in walls, ceilings and floors caused by penetrations from pipes, cables and joints in fire-rated areas. So it’s important to include passive fire protection – firestop systems – in any building design, right from the ...CP 620 Firestop foam Rigid and fast-curing firestop foam with excellent water resistance to help create a fire, smoke and moisture barrier around cable and mixed penetrations CS-S SA Light smoke and acoustic sealant Lightweight, paintable smoke and acoustic sealant for drywall joints and pipe penetrations (including CPVC) CFS-S SIL GG Firestop silicone …Features. Hilti Endo-Shield is the industry’s first LBP (Low Bio Persistent) endothermic mat for passive fire protection. Low bio persistent materials allow fibers to easily clear from the lungs compared to ceramic fibers, resulting in a safer non-carcinogenic product for the installer. Faster, easier fire protection – high flexibility and ... T Rating of the firestop system is 1-1/4 hr. If the steel sleeve extends beyond the top surface of the floor or both surfaces of the wall, the T Rating of the firestop system is 0 hr. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. November 15, 2021 F Rating — 2 Hr T Ratings — 0, 1-1/4 and 2 Hr (See Item 2)Firestop sealants, sprays, and coatings. Accessories for Firestop & Fire Protection. Software for firestop and fire protection. Over 30 years of experience in providing …System No. HW-D-0957 HWD 0957 Page: 1 of 7 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. Hilti Firestop SystemsFebruary 3, 2022 C C LAS IF I E D Classified by Underwriters Laboratories, Inc. to UL 2079 and CAN/ULC-S115 US ANSI/UL2079 CAN/ULC S115 Assembly Ratings — 1 and 2 Hr (See Item 2)F Ratings — 1 and 2 (See Item 2)Hilti has been a leading manufacturer and supplier of high-quality, easy-to-use firestop systems for over 20 years. We support you at the preparatory and execution stages of your firestop projects by offering quick planning assistance, comprehensive technical literature and application-specific training.ÐÏ à¡± á> þÿ Ó Ö ... Hilti Firestop Systems Page: 1 of 3 Firestop Joint Spray CFS-SP WB Silicone Joint Spray CFS-SP SIL F-Rating120 Minutes T-Rating60 Minutes CyclingNA Design No. HI/BPF 120-17HI/BPF 120-17 PERIMETER FIRE BARRIER SYSTEM Firestop Joint Spray CFS-SP WB ASTM E 2307 Table 1. L-Rating <1.0 SCFM/LF Reproduced by HILTI, Inc. Courtesy of …Hilti Firestop Systems CP617 / CFS-P PA / FIRESTOP BOX INSERT . Page: 3 of 7. CP 617(-L, -XL) or CFS-P PA Firestop Putty Pads, for use with flush device UL Listed Metallic Outlet Boxes installed with steel mud rings or UL Listed Nonmetallic Outlet Boxes in framed wall assemblies as specified below. When protective material is used on outlet ...SECTION 07270. Note to specifier: This specification section covers only “Through-Penetration Firestop Systems.”. Most projects require protection of “Fire-resistive construction joints” as well; a companion section 07 84 43 “Joint Firestopping” should be issued in addition. Should a Division 7 Specification Section for Firestop ... Hilti Firestop Systems. Page: 3 of 3. 9. Firestop Device* — Firestop device consisting of a steel collar with plug to be centered over opening in composite sheet. Collar shall be attached to outer surface of composite sheet on both sides of the wall with min 3/4 in. (19 mm) long sheet metal screw with 3/4 in. (19 mm) diam steelFirestop system plastic label. Identification signage for firestop installations, making them uniquely identifiable for monitoring and inspection purposes using Hilti Documentation Manager software. $23.50. Compare. Compare. Find all the accessories you need to complete your firestop and fire protection installations – designed to save lives ...5. hilti cfs-s sil gg firestop silicone sealant or hilti cfs-s sil sl firestop silicone sealant (floors only) (see table for depth). 6. minimum 1/2" bead hilti cfs-s sil gg firestop silicone sealant applied at point of contact. notes : 1. maximum diameter of opening = 32" (for normal concrete) or 7" (for precast (hollow-core) concrete). 2.Tel (800) 879-8000 or Hilti (Canada) Corporation, Mississauga, Ontario (800) 363-4458 website: www.us.hilti.com or www.hilti.ca.com Substitutions: Not permitted. Single Source: Obtain firestop documentation manager software and firestop systems for each type of penetration and construction condition indicated only from a single manufacturer.The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. The M Rating is applicable only to 1 hr rated walls and the T Rating is 0 hr. 2. Through-Penetrants — One nonmetallic pipe, conduit or tubing to be installed within the firestop system. The annular space between pipe andOur Fire Protection Consultant visit the sites of our customers and give seminars on the know-how about the Firestop system and the selected application as per the need of customer. These trainings include a wide spectrum of Firestop knowledge ranging from Products, Application, Approvals, Installation procedure, Documentation etc.Hilti (Gt. Britain) Limited, 1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY Telephone: 0800 886 100 . HILTI CP 670 . Firestop Coated Board System . The enclosed pages are taken from the . Hilti Firestop Systems Manual . Edition April 2011 . Supported by additional standard details . For Material Safety data sheets . visit the ...CP 620 Firestop foam Rigid and fast-curing firestop foam with excellent water resistance to help create a fire, smoke and moisture barrier around cable and mixed penetrations CS-S SA Light smoke and acoustic sealant Lightweight, paintable smoke and acoustic sealant for drywall joints and pipe penetrations (including CPVC) CFS-S SIL GG Firestop silicone …<iframe src="https://www.googletagmanager.com/ns.html?id=GTM-WN2QZ7Q" height="0" width="0" style="display: none; visibility: hidden" title="Google Tag Manager ...Firestop Selector. Firestop Submittals. Create an EJ on the jobsite, receive email notifications, or check status on mobile app. Compile, share, download, or save firestop systems, products and EJ submittals. Find the most relevant firestop systems and products for your firestop application. 5Hilti Firestop Systems System No. HW-D-0209 HWD 0209 Page: 1 of 2 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. February 23, 2015 1 3 2A 2B 2C 1. Floor Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) structural concrete. Hilti Firestop Systems. Wall Opening Protective Materials (CLIV, CLIV7) CP617 / CFS-P PA / FIRESTOP BOX INSERT . Page: 4 of 7. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. October 28, 2019 CP 617(-L, -XL) or CFS-P PA Firestop Putty Pads, for use with max 4 by 4 in. by 1-1/2 in. deep flush device UL Listed Metallic ...firestop system are sealed with a minimum 4 in. depth of either firmly packed minimum 4 pcf mineral wool or ceramic fiber blanket, or concrete, grout or mortar. Additionally, firestop systems utilizing a firestop device or wrap strips/steel collar installed around the penetrant Our in-house lab conducts firestop testing in accordance with ASTM E814 / UL 1479 for through-penetration firestop systems and ASTM E1966 / UL 2079 for construction-joint firestop systems. That means you can trust the F-rating and T-rating for each Hilti firestop system assembly.See all Endocrine System topicsMódulos para selar cabos/tubos dentro de um quadro de trânsito quando forem necessárias alta impermeabilidade a água e a gás, e resistência ao fogo. Intervalo de temperatura de armazenamento e transporte: 5 - 25 °C. Intervalo de resistência à temperatura: -40 - 50 °C. Intervalo de temperatura de aplicação: -20 - 50 °C.Hilti Firestop Systems System No. W-L-1506 SECTION A-A WL 1506 1. Wall Assembly — The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the ...Hilti (Gt. Britain) Limited, 1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY Telephone: 0800 886 100 . HILTI CP 606 . Flexible Firestop Sealant . The enclosed pages are taken from the . Hilti Firestop Systems Manual . Edition April 2011 . Supported by additional standard details . For Material Safety data sheetsHilti firestop systems

Hilti Firestop Systems System No. HW-D-0881 SECTION A-A HWD 0881 Page: 1 of 3 A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. November 19, 2019 A C C LAS IF E D Classified by Underwriters Laboratories, Inc. to UL 2079 and CAN/ULC-S115 USANSI/UL2079 CAN/ULC S115 Assembly Ratings — 1 and 2 Hr (See Item 2)F …. Hilti firestop systems

hilti firestop systems

A firestop documentation manager software shall be used to document, track, and maintain the passive firestop systems throughout the construction and maintenance phase of the facility. The software solution shall be used to track and document every firestop system installed on the project and each subsequent addition, change, or removal of the …2. for walls constructed of steel studs larger than 3-5/8", firestop blocks should be installed 8" deep. firestop blocks may be recessed maximum 1/2" from surface of wall. 3. apply hilti fs-one max intumescent firestop sealant, hilti cp 618 firestop putty stick, hilti cp 620 fire foam, or hilti cp 660 firestop foam into any void that mayHilti Firestop Systems. Page: 2 of 2. System No. W-L-1054. WL 1054. 2. Through-Penetrants — One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. to max 2-1/4 in. (57 mm). Pipe may be installed with continuous point contact.2. for walls constructed of steel studs larger than 3-5/8", firestop blocks should be installed 8" deep. firestop blocks may be recessed maximum 1/2" from surface of wall. 3. apply hilti fs-one max intumescent firestop sealant, hilti cp 618 firestop putty stick, hilti cp 620 fire foam, or hilti cp 660 firestop foam into any void that mayHilti Firestop Systems Page: 2 of 3 1. CONCRETE FLOOR ASSEMBLY: Max. 2 hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 100-150 pcf, with a min. thickness of 4-1/2 in. at the joint face. Overall slab thickness may vary to accommodate various blockout Hilti SL offers a range of passive firestop protection systems. Hunter and Company PLC is the owner of this website, they are a Hilti authorised distributor for Sri Lanka. You will be conducting business in Sri Lanka with this distributor and they will be fully responsible for the service levels you receive and any other business related topics.Hilti Firestop Systems. Page: 4 of 7. System No. HW-D-1011. HWD 1011. D. Framing Members* — (Not shown — Optional) — When specified in the individual U400, V400 or W400 Series Wall and Partition Design, the gypsum board on one side of the wall may be secured with furring channels and Steel Framing Members as described below: a.Hilti Firestop Speed Sleeve (CP 653 BA) for use with cable penetrations. Hilti Firestop Speed Sleeve (CFS-SL GA L) for use with cable penetrations. Hilti Modular Firestop Sleeve System (CFS-MSL) for use with new and existing cable penetrations in walls and floors. Hilti CFS-MSL Modular Sleeve (CFS-MSL S 3X2”, CFS-MSL M 3X4”, CFS-MSL L 6X4”)By now it’s well publicized—if not obvious—that many companies’ cost accounting systems are falling down on the job. They give managers incorrect product costing information, or they inundate managers with irrelevant cost information, or th...When you need to buy new parts and aren’t conveniently located near a store that carries what you want, making online purchases is a helpful option. Fortunately, it’s possible to find just about anything online these days. These guidelines ...Hilti Firestop Systems Page: 3 of 3 Design No. HI/BPF 120-31Hilti Corporation HI/BPF 120-31 Perimeter Fire Barrier System Edge of Slab QuickSeal CFS-EOS QS ASTM E2307, CAN/ULC-S115, UL 2079 (Air Leakage), ASTM E1399/E1399M (Cycling) Reproduced by HILTI, Inc. Courtesy of Intertek Grouphilti firestop systems plano, texas usa (800) 879-8000 assembly rating = 1-hr. or 2-hr. (depending on rating of wall and floor assembly) class ii movement capabilities - 50% compression or extension l-rating at ambient = less than 1 cfm / lin ft l-rating at 400°f = less than 1 cfm / lin ft mar. 28, 20230259q hwd0259q.032823.Hilti Firestop Systems. Page: 2 of 3. System No. HW-D-0049. HWD 0049. 1A. Roof Assembly — (Not Shown) — As an alternate to the floor assembly, a fire rated fluted steel deck roof assembly may be used. The roof assembly shall be constructed of the materials and in the manner described in the individual P900 Series Roof-Ceiling Design in the ...May 21, 2020 - Hilti has developed firestop solutions for an increasingly popular nonmetallic pipe: High Density Polyethylene (HDPE). Hilti firestop system C-AJ-2770 has been updated to accommodate HDPE pipe (SDR 11) that can range in size from 1-1/2” to 6”. The solution involves the “tuck-in” method using Hilti CP 648E Wrap Strip. Hilti Firestop Systems. Page: 5 of 5. System No. HW-D-0118. HW-D-0118. ManufacturerProduct DesignationSystem No. 3M Company FB 1000NSHW-S-0028 3M Company FB 2000HW-S-0002 3M Company FB 2000+HW-S-0002 A/D Fire Protection Systems Inc.A/D FireBarrier Seal N/SHW-D-0247 EGS Nelson Firestop ES 1399 …Firestop collars, wraps and bandages. Ready to use joints. Firestop putties. Firestop sealants, sprays, and coatings. Software for firestop and fire protection. Over 30 years of experience in providing internationally approved and tested firestop systems, premium software and support to help save lives and buildings from fire. Hilti Firestop Systems Page: 2 of 3 1. CONCRETE FLOOR ASSEMBLY: Max. 2 hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 100-150 pcf, with a min. thickness of 4-1/2 in. at the joint face. Overall slab thickness may vary to accommodate various blockoutFirestop system plastic label. Identification signage for firestop installations, making them uniquely identifiable for monitoring and inspection purposes using Hilti Documentation Manager software. $23.50. Compare. Compare. Find all the accessories you need to complete your firestop and fire protection installations – designed to save lives ...Hilti Firestopping Systems Hilti team members take great pride in the fact that our red toolbox is instantly recognized at construction sites around the world as a well-respected and quality brand. Hilti’s portfolio of firestop products, combined with a knowledgeable technical services team and innovative software offering, provides ... Hilti (Gt. Britain) Limited, 1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY Telephone: 0800 886 100 . HILTI CP 606 . Flexible Firestop Sealant . The enclosed pages are taken from the . Hilti Firestop Systems Manual . Edition April 2011 . Supported by additional standard details . For Material Safety data sheetsWe develop and thoroughly test firestop products to provide additional value beyond firestopping and airflow control. Our firestop systems enhance the overall building performance in many areas. They meet the latest industry needs and are easy to install, retrofit and inspect. Our passive firestop solutions for hospitals help insulate the noise ...Hilti Firestop Systems. Page: 3 of 5 HWD 0119. 2. Shaft Wall Assembly — The 1, 2 or 3 hr fire-rated gypsum board /steel stud shaft wall assembly shall be constructed of the materials and in the manner described in the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include Passive fire protection systems are designed to stop the spread of flames, smoke and toxic gases in a fire.They block gaps in walls, ceilings and floors caused by penetrations from pipes, cables and joints in fire-rated areas. So it’s important to include passive fire protection – firestop systems – in any building design, right from the ...Hilti Firestop Systems Reproduced by HILTI, Inc. Courtesy of Intertek Group March 22, 2022 Design Number HI/AF 120-02Hilti Corporation HI/AF 120-02 Applied Fireproofing Hilti CPF-ES Endo-Shield UL 1489 Min. 1 in. Tubing, 5 Layers of Hilti Endo-Shield: 2 Hour Min. 4 in. Tubing, 4 Layers of Hilti Endo-Shield: 2 Hour 3HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP672 Firestop Spray or CFS-SP WB Firestop Joint Spray *Bearing the UL Classification Mark A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. June 07, 2010 Assembly Rating — 2 Hr Nominal Joint Width — 3-1/2 In. Class II Movement Capabilities — 14% Compression and ...Find the exact system faster with Direct Search (e.g., W-L-1054, 1054, W-L …) or Advanced Search to filter by application, unique site conditions, and installation requirements for …5. Firestop System — The firestop system shall consist of the following: A. Packing Material — In 2 hr fire rated wall assemblies, min 3-3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m3/) mineral wool batt insulation firmly packed into opening as a permanent form.Simple Installations — Hilti firestop products arrive ready to use on your jobsite. Installation instructions and quick reference videos make the installing process quick and easy. System Approvals — Hilti provides firestop systems that can be used both locally and nationally in compliance with corresponding codes and regional regulations.System No. F-A-2067. FA 2067. 3. Firestop System — The details of the firestop systems shall be as follows: A. Fill, Void or Cavity Material* — Wrap Strip — Nom 3/16 in. (5 mm) thick by 1-3/4 in. (44 mm) wide intumescent wrap strip. The layers of wrap strip are continuously wrapped around pipe with ends held in place with tape.International Firestop Council Guidelines for Evaluating Firestop Systems Engineering Judgments CAN/ULC-S102-M, Standard Test Method for Surface Burning Characteristics of Building Materials. ASTM E 1399, “Test Method for Cyclic Movement and Measuring the Minimum and Maximum Joint Width of Architectural Joint Systems”Penetrations and joints in fire-resistance rated assemblies (gypsum walls, concrete floors, etc.) can be treated using tested firestop systems. These tested systems are documented and expressed in the form of listed or certified systems by nationally recognized independent testing laboratories, such as Underwriters Laboratories (UL), FM Global, …Hilti Firestop Systems Plano, Texas USA (800) 879-8000 WJ UL SYSTEM NO. W-J-8047 MULTIPLE PENETRATIONS THROUGH CONCRETE WALL OR BLOCK WALL ASSEMBLY F-RATING = 2-HR. T-RATING = 0-HR. L-RATING AT AMBIENT = 5 CFM / SQ FT L-RATING AT 400°F = 2 CFM / SQ FT Aug. 25, 20228047f WJ8047f.082522. …Hilti Firestop Systems Design Number HI/AF 120-01Hilti Corporation HI/AF 120-01 Applied Fireproofing Hilti CPF-ES Endo-Shield ASTM E1725 Ratings: Min. 1 in. Tubing, 3 Layers of Hilti Endo-Shield: 1 Hour Min. 1 in. Tubing, 5 Layers of Hilti Endo-Shield: 2-1/2 Hour Min. 4 in. Tubing, 4 Layers of Hilti Endo-Shield: 2 Hour Reproduced by HILTI, Inc.Hilti Firestop Systems. Page: 2 of 2. 3. Batts and Blankets* — Nom 1-1/2 or 2 in. (38 or 51 mm) thick glass fiber batt or blanket (min 3/4 pcf or 12 kg/m3) jacketed on the outside with a foil-scrim-kraft facing. Longitudinal and transverse joints sealed with aluminum foil tape. During the installation of the fill material, the batt or Hilti has been a leading manufacturer and supplier of high-quality, easy-to-use firestop systems for over 20 years. We support you at the preparatory and execution stages of your firestop projects by offering quick planning assistance, comprehensive technical literature and application-specific training.Hilti Firestop Systems 1. Wall Assembly — Min 4-1/2 in. (114 mm) thick steel-reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) structural concrete. Wall may also be constructed of any UL Classified Concrete Blocks*Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. October 7, 2022 C C LAS IF E D Classified by Underwriters Laboratories, Inc. to UL 2079 and CAN/ULC-S115 US Hilti Firestop Systems ANSI/UL2079 CAN/ULC S115 Assembly Ratings — 1, 2, 3 and 4 Hr (See Item 2)F Ratings — 1, 2, 3 and 4 Hr (See Item 2) Nominal Joint Width - 7/8 ...Firestop putties. Firestop sealants, sprays, and coatings. Software for firestop and fire protection. Over 30 years of experience in providing internationally approved and tested …Every Hilti product and system is backed with research, training, software, service and support. We also test our firestop products to exacting international standards and all our systems and software are based on more than 30 years of Hilti research and development. We are inspired to make a difference in our customers’ businesses.Hilti Academy. Select a course and let the learning begin. If you have not yet registered, you will first be directed to our registration page. Visit Hilti Academy. Hilti has power tools, grinders, drills, and saws as well as fasteners, anchors, design and layout software and services for construction professionals.A: When first accessing the Hilti Construction Platform, you will see five (5) options allowing a range of services and functionality for Engineering Judgments to firestop system search and submittals: Hilti fire protection specialists have performed extensive testing in both through-penetration and construction joint firestop applications. <iframe src="https://www.googletagmanager.com/ns.html?id=GTM-WN2QZ7Q" height="0" width="0" style="display: none; visibility: hidden" title="Google Tag Manager ... hilti firestop systems plano, texas usa (800) 879-8000 assembly rating = 1-hr. or 2-hr. (depending on rating of wall and floor assembly) class ii movement capabilities - 50% compression or extension l-rating at ambient = less than 1 cfm / lin ft l-rating at 400°f = less than 1 cfm / lin ft mar. 28, 20230259q hwd0259q.032823.3. Firestop System — The firestop system shall consist of the following: A. Packing Material — Min 2-1/2 or 3-3/4 in. (64 or 95 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation, firmly packed into the opening as a permanent form for 1 or 2 hr rated walls, respectively. Mineral wool to be recessed from both sides of the ...4. apply hilti fs-one max intumescent firestop sealant, hilti cp 618 firestop putty stick, hilti cp 620 fire foam, or hilti cp 660 firestop foam in any void that may exist (into interstices of cables, between cables and cable tray, or between firestop blocks), to maximum extent possible. 5. for walls constructed of steel studs larger than 3-5/8 ...Firestop and fire protection. Over 30 years of experience in providing internationally approved and tested firestop systems, premium software and support to help save lives and buildings from fire. Firestop devices and sleeves Explore our pre-formed firestop sleeves and cast-in devices, designed for easier installations and inspections when ...Firestop blocks and plugs. Technical Details. Search our pre-formed firestop blocks and plugs for cable, pipe and mixed penetrations, designed for easy repenetration while reducing dust and airborne fiber particles. 2 Products All prices discounted net. Hilti replacement parts are available online in the United States via the Hilti website. Online retailers such as Amazon, Brockwhite and eBay also offer a varied supply of Hilti replacement parts.Passive fire protection systems are designed to stop the spread of flames, smoke and toxic gases in a fire. They block gaps in walls, ceilings and floors caused by penetrations from pipes, cables and joints in fire-rated areas. So it’s important to include passive fire protection – firestop systems – in any building design, right from the ...Through a combination of innovative products, software and service offerings, Hilti can provide the most comprehensive firestop systems solution. We offer a wide range of firestop products for many different applications and solutions, tested to the most stringent international standards such as ASTM and UL complying to the need of our local building …Firestop collars, wraps and bandages. Ready to use joints. Firestop putties. Firestop sealants, sprays, and coatings. Accessories for Firestop & Fire Protection. Over 30 years of experience in providing internationally approved and tested firestop systems, premium software and support to help save lives and buildings from fire.Our Fire Protection Consultant visit the sites of our customers and give seminars on the know-how about the Firestop system and the selected application as per the need of customer. These trainings include a wide spectrum of Firestop knowledge ranging from Products, Application, Approvals, Installation procedure, Documentation etc.Hilti Firestop Systems System No. F-A-2054 SECTION A-A FA 2054 Page: 1 of 2 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 21, 2020 F Rating — 3 Hr T Ratings — 0 and 3 Hr (See Item 3) L Rating (Without Movement) At Ambient — Less Than 1 CFM/sq ft (See Item 3 and Table 1)Passive fire protection systems are designed to stop the spread of flames, smoke and toxic gases in a fire.They block gaps in walls, ceilings and floors caused by penetrations from pipes, cables and joints in fire-rated areas. So it’s important to include passive fire protection – firestop systems – in any building design, right from the ...Plan, install and manage firestop solutions. Hilti's Firestop Selector can help trades, firestop specialty contractors and architects be more productive on the jobsite and in the office. Login using your Hilti Online credentials or register for a new account to: View more than 1,550 trusted firestop systems. Save systems to projects for submittal.The F, FH Ratings of the firestop system are equal to the fire rating of the wall assembly. 2. Metallic Sleeve — (Optional) - Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or Schedule 5 (or heavier) steel pipe or min 0.016 in. thick (0.41 mm, No. 28 ga) galv steel sleeve installed flush with wall surfaces. At Hilti, we have code compliant firestop solutions covering a wide range of applications that are relevant to interior finishing, mechanical, electrical, energy and industry and facade contractors. Our solutions come with comprehensive approval documentation, and are tested in accordance with AS1530.4 and assessed in accordance with AS4072.1.Hilti Firestop Systems System No. W-L-7042 SECTION A-A WL 7042 A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. October 12, 2017 A 3 1A 2 3 1B C C LAS IF E D Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US ANSI/UL1479 (ASTM E814) CAN/ULC S115 1/2" on each side of wall to accommodate firestop sealant. 7. minimum 1/2" depth hilti cp 606 flexible firestop sealant on both sides of a gypsum wall assembly. notes : 1. as an alternate to ceiling runner in item no. 3, ceiling runners, manufactured by brady construction innovations, inc., dba sliptrack systems, metal-lite, Firestop coating system and mortar Page 155 Page 156 Firestop wrap and foam Firestop wrap stirp CP 648-E Firestop foam CP 620 Page 157 Page 158 Constrution chemicals filling foam Filling form CF-F Page 159 Accessories Accessories for firestop sealants and firestop foams Page 1608. hilti cp 767 speed strips or mineral wool safing (min. 4 pcf density) compressed 50% and inserted into joint, flush with both sides of wall. 9. minimum 1/8" (wet) thickness hilti cfs-sp wb firestop joint spray to completely cover mineral wool and to overlap a minimum 1/2" onto gypsum wall and metal deck, on both sides of gypsum wall assembly ... Firestop system plastic label. Identification signage for firestop installations, making them uniquely identifiable for monitoring and inspection purposes using Hilti Documentation Manager software. $23.50. Compare. Compare. Find all the accessories you need to complete your firestop and fire protection installations – designed to save lives ... Hilti has successfully tested and certified a variety of our systems, from those that use sealants, such as FS-ONE Max, to those that use preformed devices, such as the speed sleeve CP 653 or firestop blocks CFS-BL. Being the first to market with 8 Underwriters Laboratories (UL) certified systems with M-ratings tested to US standard UL 1479 is ...1/2" on each side of wall to accommodate firestop sealant. 7. minimum 1/2" depth hilti cp 606 flexible firestop sealant on both sides of a gypsum wall assembly. notes : 1. as an alternate to ceiling runner in item no. 3, ceiling runners, manufactured by brady construction innovations, inc., dba sliptrack systems, metal-lite, HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP672 Firestop Spray or CFS-SP WB Firestop Joint Spray *Bearing the UL Classification Mark A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. June 07, 2010 Assembly Rating — 2 Hr Nominal Joint Width — 3-1/2 In. Class II Movement Capabilities — 14% Compression and ...Hilti Firestop Systems SheetDrawing No. HILTI, Inc. Date Scale Saving Lives through Innovation and Education HWD 1 of 2 1/4" = 1" UL/cUL SYSTEM NO. HW-D-0824a ASSEMBLY RATING = 1-HR. OR 2-HR. CLASS II MOVEMENT CAPABILITIES - 25% COMPRESSION OR EXTENSION TOP OF WALL JOINT : GYPSUM SHAFT WALL ASSEMBLY CROSS-SECTIONAL VIEW Plano, Texas USA (800 ... this firestop selector and submittal page is moving Make the switch over to access the new firestop selector for planning, installing and managing firestop solutions Try the new …The joint system shall consists of the following: A. Fill, Void or Cavity Material* - Sealant — A min 1/4 in. (6 mm) or min 1/2 in. (13 mm) thickness of fill material installed within the joint, flush with each surface of the wall, as specified in Table below. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP606 Flexible Firestop Sealant5. Firestop System — The firestop system shall consist of the following: A. Fill, Void or Cavity Materials*- Sealant — Min 1/2 in. (13 mm) bead of fill material applied around periphery of floor sink at interface with bottom surface of floor. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE Sealant or FS-ONE MAX Intumescent SealantHilti Firestop Systems CEJ 421 P Page: 1 of 4 Reproduced by HILTI, Inc. Courtesy of Intertek Group June 20, 2014 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING 1-HR. 1-HR. APPLICATION THICKNESS 1/8" WET FILM (1/16" DRY) 2mm (0.079") WET FILM …DAP PRODUCTS INC — DAP Firestop Sealant EGS NELSON FIRESTOP — ES 1399 Sealant HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP601S, CFS-S SIL GG, CP606, FS611A, FS-ONE Sealant or FS-ONE MAX Intumescent Sealant 3M COMPANY — FB 1000NS, FB 2000, FB 2000+, FD-10+, CP 25 WB+ NATIONAL GYPSUM CO — FS-90. Hilti Firestop Systems. System No ...The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. The M Rating is applicable only to 1 hr rated walls and the T Rating is 0 hr. 2. Through-Penetrants — One nonmetallic pipe, conduit or tubing to be installed within the firestop system. The annular space between pipe and Hilti Academy. Select a course and let the learning begin. If you have not yet registered, you will first be directed to our registration page. Visit Hilti Academy. Hilti has power tools, grinders, drills, and saws as well as fasteners, anchors, design and layout software and services for construction professionals. Hilti has successfully tested and certified a variety of our systems, from those that use sealants, such as FS-ONE Max, to those that use preformed devices, such as the speed sleeve CP 653 or firestop blocks CFS-BL. Being the first to market with 8 Underwriters Laboratories (UL) certified systems with M-ratings tested to US standard UL 1479 is ...To help avoid lengthy delays in project sign-off, use the cloud-based Hilti Documentation Manager to record, track, and report on all installed anchor, support and firestop systems — regardless of manufacturer. With an easy to use online back office interface, progress reports and work permits can be produced with a click of the mouse.Hilti Firestop Systems Page: 1 of 3 Reproduced by HILTI, Inc. Courtesy of Intertek Group December 26, 2019 2D 2C 2B 2C FOIL FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING2 Hour2 Hour T-RATING 0-1 Hour (see Item 2G) 0-1 Hour (see Item 2G) APPLICATION THICKNESS 1/8 in. wet film (1/16 in. dry)Our Hilti firestop solutions for linear and perimeter joints include: Our Hilti Sealant and Hilti Joint Spray – our most widely used firestop products for edge of slab solutions. Our Hilti Top Track Seal – wraps around a track between gypsum board joints and flat concrete slabs. A wide range of firestop systems for exterior use.At Hilti we can help you with specification and design for passive fire protection systems. We also offer cutting-edge products, easy to use design software and technical backup onsite, online and on the phone. Just get in touch with your local Hilti Technical Advisory Service if you can’t find what you need online.UL approval R13203 for Hilti steel deck fasteners X-ENP-19, X-HSN 24, X-EDN19, X-EDNK22, S-MD 12-24x1-5/8 and S-MD05Z 5.5x40 for use in construction numbers 58, 87, 156 and 157, delivered by UL on June 13, 2013. Related products: X-HSN 24 Metal deck fasteners (collated), X-ENP MXR Metal deck fasteners (collated) Veeva Systems News: This is the News-site for the company Veeva Systems on Markets Insider Indices Commodities Currencies Stocks. Floral syndicate